Item

Performance characteristics

Type

High precision

Applicable Controller

GD-C1, GD-C2, GD-C3

Sensing Range (Between Sensor Heads)

30 mm 1.181 in or less

Detectable Sheet Thickness :Applicable Controllers GD-C1/C2: Setting Distance 20 mm 0.787 in

Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 1 mm 0.003 to 0.039 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.

Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 20 mm 0.787 in

Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.3 mm 0.0004 to 0.012 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 2 mm 0.002 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.

Detectable Sheet Thickness: Applicable Controllers GD-C1/C2: Setting Distance 30 mm 1.181 in

Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 0.5 mm 0.003 to 0.020 in
Aluminum: 0.03 to 2 mm 0.001 to 0.079 in
Copper: 0.03 to 2 mm 0.001 to 0.079 in
Brass: 0.03 to 2 mm 0.001 to 0.079 in
Stainless steel (SUS304): 0.1 to 2 mm 0.004 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.

Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 30 mm 1.181 in

Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 1 mm 0.002 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.

Environmental Resistance: Protection

IP67 (IEC)

Environmental Resistance: Ambient Temperature

-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit

Environmental Resistance: Ambient Humidity

45 to 85 % RH, Storage: 35 to 95 % RH

Environmental Resistance: Vibration Resistance

10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each

Environmental Resistance: Shock Resistance

1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each

Material

Enclosure: Polyalylate

Cable

Sender: 0.3 2 single core shielded cable, 3 m 9.843 ft long
Receiver: 0.1 2 2-core shielded cable, 3 m 9.843 ft long

Cable Extension

Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.