BENEFIT
-
Permanent Static Dissipative
-
Insensitive to environment
-
Special design for cleanroom application
STOCK AVAILABILITY (SLEEVING FOR WIRES & ETC)
Inner Diameter (mm) |
Outer Diameter (mm) |
Standard Roll (Meter) |
Part No. |
3 |
3.8 |
100 |
ESD 030 / 038 |
6 |
6.8 |
100 |
ESD 060 / 068 |
10 |
10.8 |
100 |
ESD 100 / 108 |
15 |
15.9 |
100 |
ESD 150 / 159 |
28 |
29 |
5m |
ESD 280 / 290 |
31 |
33 |
5m |
ESD 310 / 320 |
40.5 |
43 |
5m |
ESD 405 / 430 |
SPECIFICATION
Surface Resistivity |
8 * 10 to power of 8 |
Decay time at centre of tube |
0.5 to 1.2 seconds |
Decay time at end of tube |
0.8 to 1.3 second |
Float voltage observed |
0V to 3 V |
Peel off voltage observed |
0V to 3V |
The Sleeving are free from silicon |
|
PROCEDURE
OUTGASSING – Three samples of Bluish Sleeving were used and placed in an outgassing vessel at 85 Degree C. It was then flushed continually for three hours at 50ml/min with grade 5 nitrogen. A carbotrap ‘B’ / carbotrap ‘C’ tube were then used to trap the outgassing constituents after which analyzing using GC/MS with ATD.
FTIR / SILICONE OIL / HYDROCARBONS – The presence of silicone oil and hydrocarbons were extracted in solvent soluble residue from one piece of 15.5 “ of ESD Bluish Sleeving. Both the inner and outer surfaces, a total of 121cm square, were rinsed with 10ml of hexane and isopropanol by mixing a portion of 1 : 1 (v/v) of the solvent solution. A clean 30ml glass beaker was used to collect the rinsate. The solvent solution was evaporated to dryness. Thereafter, FTIR / HATR was used to analyze for the presence of silicone oil and hydrocarbons on any residue rinsed from the sample.
IONIC CONTAMINATION – A ESD Bluish Sleeving sample were divided into three sections to test for ionic contamination. Three pre-clean glass beaker containing 10ml of de-ionized water was given one section of the sleeving sample each and then capped off to prevent evaporation. The glass beakers were then placed in an 80 Degree C oven. The water extract was then analyzed using ion chromatography. A hand measured apparent surface area of 10.2cm square was used to calculate the results.
RESULTS
OUTGASSING - Below are the data obtained from using the following chemical
COMPOUND INDENTIFICATION |
Section 1 Sample |
Section 2 Sample |
Section 3 Sample |
Average |
BHT |
13 ug/g |
12 ug/g |
13 ug/g |
13 ug/g |
KETONES |
25 ug/g |
27 ug/g |
23 ug/g |
25 ug/g |
SILOXANE |
0 ug/g |
1 ug/g |
0 ug/g |
1 ug/g |
HYDROCARBON, OTHERS |
16 ug/g |
15 ug/g |
19 ug/g |
17 ug/g |
TOTAL |
54 ug/g |
55 ug/g |
55 ug/g |
56 ug/g |
FTIR / SILICONE OIL / HYDROCARBONS
- Below shown was obtain from the analyzed result on one section of the Sleeving.
|
Section 1 Sample |
Limits |
SILICONE OIL |
9 |
As per customer's specification |
HYDROCARBONS |
158 |
As per customer's specification |
Note: Result for both the silicone oil and hydrocarbons are in nanograms/cm square surface area.
IONIC CONTAMINTAION - The result tested as follows
SAMPLE |
Section1 Sample (ug/cm square) |
Section 2 Sample (ug/cm square) |
Section 3 Sample (ug/cm square) |
Average |
Limits |
AMMONIUM |
0.017 |
0.018 |
0.015 |
0.017 |
As per customer's specification |
BROMIDE |
0.007 |
0.008 |
0.004 |
0.006 |
|
CALCIUM |
0.022 |
0.020 |
0.020 |
0.021 |
|
CHLORIDE |
0.010 |
0.009 |
0.011 |
0.010 |
|
FLUORIDE |
0.030 |
0.031 |
0.030 |
0.030 |
|
MAGNESIUM |
0.001 |
0.001 |
0.001 |
0.001 |
|
NITRATE |
0.003 |
0.003 |
0.004 |
0.003 |
|
NITRITE |
0.000 |
0.000 |
0.000 |
0.000 |
|
PHOSPHATE |
0.078 |
0.080 |
0.070 |
0.076 |
|
POTASSIUM |
0.010 |
0.010 |
0.011 |
0.011 |
|
SODIUM |
0.154 |
0.152 |
0.147 |
0.151 |
|
SULFATE |
0.000 |
0.004 |
0.001 |
0.002 |
|
TOTAL SUM |
0.332 |
0.336 |
0.314 |
0.327 |
ROHS FOR SPIRAL COIL - On analysis, the following result were obtain:
Test Parameter |
Digestion / Extraction Method |
Analysis Method |
Result, ppm (w/w) |
Mercury (Hg) |
AC/RoHS/0010 Ver1.1/05 Wet Acid Digestion (Microwave) |
CVAAS |
ND |
Lead (Pb) |
AC/RoHS/0007 Ver1.0/05 Dry Ashing |
ICP-AES |
ND |
Cadmium (Cd) |
AC/RoHS/0007 Ver1.1/05 Wet Acid Digestion (Microwave) |
ICP-AES |
ND |
Hexavalent Chromium (Cr 6+) |
Ac/RoHS/0011 Ver1.0/05 EPA 3060A / 7196A (Modified) |
ND |
|
Polybrominated Biphenyls (PBB) |
AC/RoHS/0012 Ver1.1/05 (Microwave) |
GC-MS |
ND |
Plybrominated Diphenyl Ethers (PBDEs) |
AC/RoHS/0012 Ver1.1/05 (Microwave) |
GC-MS |
ND |
REMARKS
-
Sample was prepared as in AC/ROHS/0006 Ver1.0/05 and all the methods listed above are reference to the IEC 111/24/CD/Ed.1- Procedure for determination of levels of regulated Substances in Electrotechnical Products.
-
CVAAS = Cold Vapour Atomic Absorption Spectrometry
ICP – AES = Inductively- Coupled Plasma – Atomic Emission Spectrometry
GC-MS = Gas Chromatography – Mass Spectrometry -
The Method detection limits(MDL) for Lead, Cadmium, Polybrominated Biphenyls and Polybrominated Diphenyl Ethers = 1 ppm each
-
The Method detection limits(MDL) for Hexavalent Chromium = 2ppm
-
The Method detection limits(MDL) for Mercury = 0.5ppm
-
“ND” = Not detected (Less than or equal to 5ppm)
Inquiry - ESD Dissipative Sleeving