Item |
Specifications |
---|---|
Product Number |
CX-441 |
Part Number |
CX-441 |
Regulatory compliance |
EMC Directive, RoHS Directive |
Adjustable range |
20 to 50 mm 0.787 to 1.969 in |
Sensing range(with white non-glossy paper) |
2 to 50 mm 0.079 to 1.969 in |
Hysteresis |
2 % or less of operation distance(with white non-glossy paper) |
Repeatability |
Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper) |
Supply voltage |
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption |
20 mA or less |
Output |
NPN open-collector transistor |
Inquiry - CX-441