Share:


DSRD07A-KA

* Maximum Vertical Transportable Mass: When the power is turned off, or when in an all windings off situation, the actuator loses its thrust force or holding force. As such, it can no longer keep the load in position or withstand an external force.
* Maximum Speed: Use each actuator at or below the following maximum speed in an operating temperature range of 0 to +10˚C: DRS28: 20 mm/s.
* Maximum Thrust Force: The maximum thrust is measured during constant-speed operation in the horizontal direction with no load applied to the moving parts (joint). Thrust force varies with load mass and acceleration.
* Maximum Holding Force Power ON: The holding force is the value when the automatic current cutback function is ON (40%).
* Resolution: A desired resolution can be set from among four levels.



 Inquiry - DSRD07A-KA