Share:


GX-F8B

Max. Operation Distance

2.5 mm 0.098 in plus or minus 8 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.

Stable Sensing Range

0 to 2.1 mm 0 to 0.083 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

Standard Sensing Object

Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in

Hysteresis

20 % or less of operation distance(with standard sensing object)

Repeatability

Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less

Supply Voltage

12 to 24 V DC +10/-15 % Ripple P-P 10 % or less

Current Consumption

15 mA or less

Output

NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current)

Output: Output Operation

Normally closed

Output: Utilization Category

DC-12 or DC-13

Max. Response Frequency

500 Hz

Operation Indicator

Orange LED(lights up when the output is ON)

Ambient Temperature

-25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※