Inverter VFD Frequency AC Drive S310-201-H1D New 1 Phase 220V 4.2A 0.75KW 1HP
Product Specifications
Single/Three Phase, 200~240V model
S310-xxx-XXX |
2P5 |
201 |
202 |
Horsepower () |
0.5 |
1 |
2 |
Max Applicable Motor Output (KW) |
0.4 |
0.75 |
1.5 |
Rated Output Current(A) |
3.1 |
4.2 |
7.5 |
Rated Capacity(KVA) |
0.88 |
1.60 |
2.9 |
Max. Input Voltage |
Single Phase: 200~240V +10%-15%, 50/60Hz+-5% |
||
Max.Output Voltage |
Single Phase: 200~240V |
||
Input Current(A) |
5.4 |
10.4 |
16 |
Net Weight(KG) |
0.97 |
1.07 |
|
Net. Weight(KG)Keypad |
1.0 |
1.1 |
|
Allowable momentary power loss time (second) |
1.0 |
1.0 |
2.0 |
General Specifications
Item |
S310 |
|
Control |
V/F |
|
Frequency Control |
Range |
0.01~400.00Hz |
Setting Resolution |
Digital: 0.01Hz, Analog: 0.06Hz/60Hz(10bits) |
|
Keypad Setting |
Set directly with “up” “down” keys or the VR on the keypad |
|
Display Function |
Five digital LED and status indicator: display frequency/Inverter parameter/Fault Log/Program Version |
|
External Signal setting |
1. External potentiometer 0-10V/0-20mA 2. Provides up/down controls, speed control or automatic procedure control with multifunctional contacts on the terminal block(TM2) |
|
Frequency Limit Function |
Upper/lower frequency limits |
|
General Control |
Carrier frequency |
1~12KHz |
V/F pattern |
6 fixed patterns, 1 programmable curve |
|
Acc/Dec control |
Acc/Dec time(0.1~3,600 seconds) |
|
Multifunction analog output |
4 functions (refer to description on 2-12) |
|
Multifunction input |
10 functions |
|
Multifunction output |
6 functions |
|
Other Functions |
Momentary Power Loss Restart, Overload Detection, 8 preset speeds, 2 3-wire Control, torque boost, Slip Compensation, Frequency Upper/Lower Limit, Modbus slave and PC/PDA Link, Auto Restart. |
|
Communication Control |
1. Control by RS485 2. One to one or one to many (RS485 ONLY) control. 3. BAUD RATE/STOP BIT/PARITY/bit can be set |
|
Braking Torque |
About 20%, standard model the specified external braking resistors can provide 100% |
|
Operation temperature |
14-1200F(-10~500C) |
|
Storage temperature |
4-1400F(-20~600C) |
|
Humidity |
0-95% Relative Humidity (Non-condense) |
|
Vibration |
1G(9.8m/S2) |
|
Enclosure |
IP20 |
|
Protective Functions |
FUSE |
The motor stops after FUSE melt |
Over Voltage |
200V class: DC Voltage>410V |
|
Under Voltage |
200V class: DC Voltage<190V |
|
Momentary Power Loss Restart |
Restart can be initiated with spin start |
|
Other Function |
Over torque detection, error contact control, reverse prohibit, prohibit for direct start after power up and error recovery. |